products
Adjustable Over Voltage Under Voltage Protector Din Rail Circuit Breaker
Adjustable Over Voltage Under Voltage Protector Din Rail Circuit Breaker
Adjustable Over Voltage Under Voltage Protector Din Rail Circuit Breaker
Adjustable Over Voltage Under Voltage Protector Din Rail Circuit Breaker
Adjustable Over Voltage Under Voltage Protector Din Rail Circuit Breaker
Adjustable Over Voltage Under Voltage Protector Din Rail Circuit Breaker

Adjustable Over Voltage Under Voltage Protector Din Rail Circuit Breaker

Remote Control

Protect against

Over Voltage
Under Voltage
Surges/Spikes
Short Circuit Protection
Overload Protection
Leakage Protection

Online Inquiry


Circuit Breaker(Automatic Over and Under Voltage Protector) complies with modular design standards. the circuit boards of products adopt good quality electronic components with reliable performance. when the power situation is unstable. It's protection function will be automatically activated. once the voltage exceeds the limited range of products, it will automatically cut off so as to protect the safely of electrical equipment and persons. The device will re-supply in 1 minute, when the power returns to normal.

The green indicator display, when the power is normal supply.

The red indicator display, when the power over voltage or under voltage.

Installing: 35mm Din rail.




Purpose
It is intended for a circuit of AC 50Hz/60Hz with maximum rated current of 63A to protect it and the equipment involved against overvoltage, low voltage, current surge, leakage, lightning, etc.
It is applicable to such electrical equipment as communication base stations, repeaters, video surveillance, Safety City, cable TV, digital TV, network switches, optical transceivers, meteorological telemetry stations, seismic detection stations in various conditions.

Features
Detection before closing: The automatic reclosing power protection switch monitors the circuit and will not close in occurrence of any overvoltage, leakage, overcurrent and other failures.
Overvoltage protection: When the voltage between the live wire and naught wire of the input terminal is greater than the set value, it will trip the switch for protection.
Low voltage protection: When the voltage between the live wire and naught wire of the input terminal is less than the set value, it will trip the switch for protection.
Overcurrent protection: When the actual current is greater than or equal to 1.15 times the rated current for 3 seconds, it will trip the switch for protection.
Leakage protection: When the leakage current exceeds the set value or an electric shock occurs, the automatic reclosing switch will be disconnected within 0.1 seconds to ensure personal safety.
Automatic disconnection when power's off: The switch will be automatically disconnected when the circuit is powered off, and will be automatically reclosed after detecting a normal power supply restored.
Intelligent leakage identification: Automatically detect before closing if the voltage is normal and the Neutral line is well-connected and never close in case of any failure.
Automatic reclosing: Automatically reclose after a certain time interval if the above failure occurs.
Automatically save tripping information: Automatically save such tripping information as tripping time, tripping type (cause), voltage, current and leakage current for failure analysis.

3.Main technical parameters


Items Specifications
Deccription Overy Voltage/Under Voltage/Over Current/Electric Leakage Integrated Protective Device
Lightning Reistance III class
Over Current Protection  AC 1-63A adjustable 
Rated AC Voltage 230V/ 50Hz
Electric Leakage 10-90mA adjustable 
Max Loading Power 4.4KVA 6.6KVA 8.8KVA
Over-Voltage Action Cut-Off Value 240-300VAC adjustable 
Under-Voltage Action Cut-Off Value 140-190VAC adjustable 
Power Delay after Power Failure 30s
Actiont Delay Time Less than 0.1s
Self Power Consumption Less than 3W
Install Way DIN-rail mounting
Warranty 1 Year
Efficiency 97%
Electrical Life 100K times at least
Standard IEC60898-2
Outline Size 73x76x67mm 
Certificate  CE, ISO



Wiring:you don't need to connect to GND, if you don't have GND

Note 1: This switch cannot be used as a master breaker. Please install a miniature circuit breaker as an overload short-circuiting fitting in front of the switch.
Note 2: Please adjust the current after installation.
Note 3: This product is designed without isolation function. Please disconnect the front breaker before repairing the circuit.